Logo

Trench Drain FAQ

General Trench Drains

Are expansion joints required?

Yes. Install one on each side of the drain, running perpendicular to it.

How do I convert feet to meter sections?

Divide the number of feet by 3.28 to get the number of meter sections.

How many feet are in a meter?

There are 3.28 feet in a meter.

Smith/ACO Trench Drain

Are the closing end caps on the 9818 series universal?

Yes. One end cap fits either end of any channel section.

Is there an installation device for the 9812 series?

Yes. Brackets are welded to the frame and supplied with bolts.

Are concrete anchors required on the 9816 series?

Yes. Use 8 anchors per 1-meter channel section.

Is an 8" wide polyethylene system offered?

No. The 9812 series is a 10" wide, high-capacity, presloped fiberglass system.

Is the 9818 series available with an integral brass rail?

No. Galvanized and stainless steel rails are offered.

What is the maximum discharge water temperature for polymer concrete?

180°F.

Are end caps universal for the 9814 and 9818 series?

Yes. One cap fits either the shallow or the deep end.

What is equal to the Polydrain 900 series catch basin?

The 9860 series catch basin, used with the 9814 series.

What is equal to the Zurn Z806 series?

The 9810 series.

How are preformed outlet cutouts removed in polymer concrete?

Drill around the perimeter of the cutout, break out the center with a cold chisel and hammer, then finish the edge with a hand grinder.

Is there a polymer concrete option for chemical exposure?

Yes. The 9814 and 9818SS series are available in vinylester.

What is equal to the Polycast 600 series?

The 9814 series.

Is a threaded connection available?

No. Only a 4" no-hub outlet is offered, and the end user installs it.

Is there a stock stainless steel trench drain?

Yes. The 9660 series is available in 304 or 316 stainless steel.

Are sediment buckets available?

Yes, in plastic and in stainless steel.

Is there a strainer for the 9818 series?

Yes. The 9854 strainer is made of plastic.

Is an aluminum trench drain offered?

No.

Is the 9818 series IAPMO approved?

No. IAPMO has no listing for linear drainage systems, so there is no approval number.

Enviro-Flo® II Trench Drain

Is a polyethylene sport track system offered?

No.

What is the maximum discharge water temperature for polypropylene?

180°F.

Are catch basins available for the 9930 and 9931 systems?

Yes. The 9930 uses the 9935 catch basin, and the 9931 uses the 9936 catch basin.

What is the shallowest channel for a 4" horizontal outlet?

Use no shallower than a #10, for both polymer concrete and Enviro-Flo II, to leave enough concrete above the pipe.

Is there a universal end cap?

Yes. A shallow cap and a deep cap fit all 20 sections. The shallow cap also fits the catch basin.

Is a 24" square polypropylene catch basin available?

No. Only the in-line catch basin is available.

What is equal to the Zurn Z-886?

The 9930 and 9931 polypropylene series.

Is a heat welding guide available?

No. We are investigating whether one is needed.

Trench Drain Grates

Are aluminum grates available for polymer concrete or polypropylene systems?

No.

Is a nickel bronze grate available?

The closest option is stainless steel.

Is an ADA grate available in ductile iron?

Yes. Part 9870-477-ADA fits the 9816, 9818, and 9931 systems.

Is a slotted grate available for polymer concrete?

No. It was discontinued because of high breakage.

What is the difference between the 440-VF and 440-VF2?

The 440-VF has bars on 1" centers. The 440-VF2 has bars on 5/8" centers.

Is there a polymer concrete grate for Smith/ACO?

No. It was discontinued because of high breakage.